Automated Versus Manual Thermograms From 19 Runners
Evidence note: the lifestyle scene is a fictional AI-assisted illustration. It does not depict a study participant, clinician endorsement, diagnosis, or before/after result.
Why this active-life question matters
Seventy-six images from 19 recreational runners were analyzed before and after a 10-km outdoor run. The practical value is not a promise that one routine or product works for everyone. It is a closer look at how a specific exposure was measured, which comparison was made, and how much uncertainty remains.
Busy adults move between climate-controlled rooms, protective equipment, repeated washing, exercise, footwear and bathing. Those settings can change surface water, temperature, occlusion and measurement conditions. A reading such as transepidermal water loss is useful only when the anatomical site, acclimation, environment and timing are kept in view.
Study snapshot
| Evidence element | What the paper reports |
|---|---|
| Population and design | Seventy-six images from 19 recreational runners were analyzed before and after a 10-km outdoor run. |
| Comparator | Automated software versus two manual region-of-interest methods |
| Timepoint/exposure | Before and after one 10-km run |
| Numerical result | Agreement was high (CCC 0.95–0.98), MAE 0.3–0.5°C and bias 0.0°C; automated analysis took 2.0 hours versus 13.9 and 28.7 hours manually. |
| Important limitation | This validates analysis workflow rather than clinical interpretation; one running event and 19 runners do not prove thermography detects injury. |
| Funding | No grant information was displayed in the PubMed record reviewed. |
| Conflicts | Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests:Jose I. Priego-Quesada reports article publishing charges, equipment, drugs, or supplies, and travel were provided by Spain Ministry of Science Innovation and Universities. For this research, although the ThermoHuman® company collaborated by providing the license of the software, they did not interfere in the analysis of the results or in the elaboration of this paper. Given their role as Associate editor, J.I. Priego-Quesada had no involvement in the peer-review of this article and has no access to information regarding its peer-review. Full responsibility for the editorial process for this article was delegated to another journal editor. If there are other authors, they declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. |
What the investigators actually did
Although different studies are using ThermoHuman software to delimitate regions of interest (ROI) of lower limbs, no study has validated this automatic analysis. This work evaluated the level of agreement and time efficiency of the automated ThermoHuman software compared with manual determination of the regions of interest in assessing lower-limb skin temperature before and after exercise. Seventy-six thermographic images from 19 recreational runners (10 males, 9 females) were analyzed before and after a 10-km outdoor run. Automated analysis using ThermoHuman was compared with Manual analysis (ROI delineation based on general template) and Manual-TH (manual replication of the same ROI delimitations generated by ThermoHuman). Agreement was assessed using concordance correlation coefficients (CCC), mean absolute error (MAE), Bland-Altman analysis, and linear mixed models. High agreement was observed between methods, with CCC values ranging from 0.95 to 0.98 and MAE between 0.3 °C and 0.5 °C, and bias of 0.0 °C for all comparisons. Mixed-model analysis revealed no significant main effect of method. Additionally, the ROI selection criterion (Manual-TH vs. Manual) did not result in significant differences. Compared with Manual (13.9 h) and Manual-TH (28.7 h), ThermoHuman required substantially less time for image analysis (2.0 h), representing time savings of 85.6 % and 93 %, respectively. In conclusion, automated analysis using ThermoHuman showed high agreement with both manual approaches, including a higher time efficiency.
How to read the result without overreaching
Agreement was high (CCC 0.95–0.98), MAE 0.3–0.5°C and bias 0.0°C; automated analysis took 2.0 hours versus 13.9 and 28.7 hours manually. This finding belongs to the cited design, population and timepoint. It should not be converted into a diagnosis, a universal rule, or proof that a cosmetic moisturizer prevents or treats disease.
This validates analysis workflow rather than clinical interpretation; one running event and 19 runners do not prove thermography detects injury. The result may still help readers notice which parts of daily life deserve attention: exposure duration, recovery time, anatomical site, product or material formulation, and whether the comparison was randomized, observational or within-person.
Questions the paper can—and cannot—answer
The paper can describe the measurements made under its stated conditions and the uncertainty visible in its design. It cannot establish that every adult will respond the same way, that a different fabric or formula will behave identically, or that a short instrumental change equals a meaningful health outcome. Numerical readings also depend on calibration, room conditions, acclimation, body site and timing.
For practical decisions, the most defensible takeaway is to separate exposure management from cosmetic care. Adjusting friction, heat, moisture, glove or clothing practices may be relevant to the activity itself. A moisturizer has a narrower role: supporting hydration, the moisture barrier and dry-skin comfort. Persistent or worsening symptoms require individualized clinical evaluation rather than extrapolation from this study.
Practical, claim-safe routine thinking
- Use the gentlest routine that fits the task and workplace rules.
- After washing, dry carefully and pay attention to repeated friction, heat and occlusion.
- For persistent cracking, rash, swelling, pain, drainage or infection concerns, seek qualified medical care.
- Do not assume that results from a study formulation, device, sock, cleanser, glove or shower system apply to a different product.
Where Dr. Arsy #003 fits—and where it does not
Dr. Arsy #003 is a cosmetic face-and-body moisturizer for hydration, moisture-barrier support and dry-skin comfort. It was not tested in the cited study, and the study’s outcomes are not being transferred to #003. This article does not claim treatment, cure, prevention, itch or pain relief, universal tolerance, pediatric safety, or 24-hour protection.
View Dr. Arsy #003 Moisturizer
Related evidence within Doctor’s Notes
- Wet-Fabric Perception Across 18 Dynamic-Friction Tests
- Lower-Leg Oxygen During Thirty Minutes of Elastic Stocking Wear
- Three Skin-Temperature Sensors in 26 Adults Exercising in Heat
- Three Wheelchair Cushions During Two-Hour Warm-Room Sitting
Primary and authoritative sources
- Primary PubMed record: Automated Versus Manual Thermograms From 19 Runners
- CDC/NIOSH: skin exposures and effects
- American Academy of Dermatology: dry-skin care
PubMed indexing identifies a bibliographic record; it is not NIH endorsement.